Tag Archives: PTFE Cover

Maintenance – How to change the Heating Element and PTFE Cover/Adhesive on your Hand Sealer

Maintenance is KEY to a long lasting impulse sealer.  Regular maintenance of your impulse sealer will ensure the longevity of your sealer.  After using between 1,000-5,000 seals, it is normal for the heating element (wire) to break .  The number is dependent on your timer setting and will vary from user to user.  Regularly replacing your sealer’s heating wire, PTFE adhesive (sticky brown protective skin under the element), and the PTFE cover (brown protective skin over the element) is essential for your sealer’s health and well-being.

Take a look at our instructional video on how to change out your heating element and insulation pieces.

Glossary of Packaging Terms

We have created a couple of glossary reference guides for our distributors.  There are so many terms to remember that we sometimes we forget too!

Click here for our A to Zs of Packaging

Click here for our Glossary of Flexible Packaging Materials

TROUBLESHOOTING – Impulse Sealers

We created this troubleshooting guide to help with our most frequently asked questions regarding sealers.

Impulse sealers (hand, foot, automatic) work in a similar manner – often, if you are having a problem with your sealer, the solution can be found in the following parts:  heating element, PTFE adhesive, PTFE cover, microswitch, mounting spring, and/or timer.  Let us know if you have a problem that isn’t listed in this guide and we can try and assist you.

  1. Check element and PTFE cover and adhesive.
    • Element: This is the wire (flat or round) that heats up to seal or cut the bag/film. Remove the PTFE cover and check that the wire is not discolored, bent, or broken.
    • PTFE Adhesive: This is the 1/2″ piece with an adhesive backing UNDER the heating element.  It should extend past the seal area 1/2″ on either side because it is the barrier between the metal machine and the metal heating element. For the PTFE adhesive, you must replace the bottom sealing strip whenever you change the element.  The adhesive serves as a barrier between the heating element and the sealer’s body.  When the sealer’s heating element has burned through the bottom adhesive and arc’ed on the sealer’s body, the element will break as well as destroy the timer.
    • PTFE Cover: The PTFE cover that goes over the heating element must be whole to prevent the plastic bags or film from sticking to the element. For the teflon cover, we recommend changing the cover BEFORE it burns through.  As the cover wears, you will see a discoloration where it comes into contact with the element, you may also notice that your element is sticking to the thermoplastic material you are sealing.  You can maneuver the cover back and forth to allow the element to come into contact with the unused portions of the PTFE cover. If you are sealing/cutting a thicker plastic material (higher amount of heat) you may go through a lot of PTFE covers.
    • We highly recommend having these parts in stock since they do wear and tear.  To purchase a replacement part which would include all three items, visit our site here.
  2. Listen for “click” from microswitch when pushing bar down. This click should occur right before the upper bar comes into contact with the lower. If there is no click try the following:
    • Hand Sealer: Slightly bend metal switch lever so that when arm of sealer is brought down, the lever makes contact with microswitch and a click can be heard.
    • Foot Sealer: Small bolt for limit switch must be tightened as needed to make contact with the microswitch.
    • Auto Sealers: A 3.5″ screw that is mounted on upper jaw must be loosened so that it will make contact with microswitch which is mounted on left side of hinge bracket.
    • Microswitches can be purchased here on our site.
  3. Mounting Spring: Make sure that the spring the element mounts on is intact. Replace if damaged.  Please check also that the mounting spring is not rusted or worn in any way as this will prevent the element from conducting heat.  Mounting springs can be purchased here.
  4. Timer Light: The light on the timer should come on briefly when the seal bar is brought down for sealing. If it does not come on, the timer PC board probably needs replacing.  Timers can be purchased here, but contact us if you cannot find the timer you are looking for.

MAINTENANCE – for your Hand Impulse Sealer

Regular maintenance of your impulse sealer will ensure the longevity of your sealer.  After using between 1,000-5,000 seals, it is normal for the heating element (wire) to break .  The number is dependent on your timer setting and will vary from user to user.  Regularly replacing your sealer’s heating wire, PTFE adhesive (sticky brown protective skin under the element), and the PTFE cover (brown protective skin over the element) is essential for your sealer’s health and well-being.

An impulse sealer’s PTFE adhesive serves as a barrier between the heating element and the sealer’s body.  When the sealer’s heating element has burned through the bottom PTFE adhesive and arc’ed on the sealer’s body, the heating element will break and may also damage the timer.

**When replacing the heating element, you MUST also replace the bottom PTFE adhesive.  Make sure the PTFE adhesive is 1/4″ and 1/2″ past the machine on both ends.  This prevents the heating element from coming in contact with the sealer’s body.

Download our instructions on how to change your sealer’s heating wire and PTFE cover and adhesive here.

We carry replacement kits for all our sealers.   If you do not find what you are looking for, contact us!